Total primary inductance was actually measured at current
flowing thru all four primaries connected in series. The current was then
doubled in order to correct for the mmf when using one primary winding only.
5V/50Hz was superimposed upon a swept DC voltage. Due to the
ac portion always being more than 15%, L was plotted versus pure Idc only.
Comparing this result with the L(I) dependency for the OPT
TI-57613-C, it is clear that this standard un-gapped core is useful for pure
well-balanced Class A operation only.
It is also interesting to note that the direct current for
Lmax as measured for L(U), obviously is so small that it is even hard do
detect. This seems to be the case for the OPT also, but for that type of
special core an inductance increase was actually detected.
From the above result it is fair to say that useful
inductance when using this transformer as an OPT is no more than 80H and
this is when the bias unbalance is no more than approximately 1mA!